Loader
Catalogue Code: NU 72 01 507

Premius 2 kVA 72V with Inbuilt Isolation transformer

  • Model
    Premius
  • Rating
    2 kVA
  • DC Volts
    72 V
  • Dimension (mm)
    190 x 490 x 590 (W x D x H)
  • Weight (kgs)
    37.5
About the product

Premius is a high efficiency single phase UPS that delivers unity power factor across its entire range. With up to 94% efficiency, N+X redundancy configuration Premius is best suited for critical applications across various segments. Premius operates in a wide input voltage window, providing constant output voltage for demanding applications.

Segments
  • Residential & SOHO
  • Healthcare
  • Infrastructure
  • Commercial
Generic Features
  • Unity power factor delivers upto 25% more active power
  • High efficiency of upto 94% for lower operating cost  
  • < 5% THDi improves UPS operative capacity
  • N+X redundancy for maximum uptime  
  • Parallelable upto 4 UPS
  • High capacity charger for quick battery recharge  
  • Inbuilt isolation transformer for reliable protection
  • Programmable output socket for critical loads
  • Wide communication option
General
  • Capacity: 2 kVA
  • Isolation Transformer: Yes
  • Overall Efficiency: ≥83% @100% Load
  • Inverter Efficiency: 88%
  • ECO Mode: YES
Input Parameters
  • Input Voltage: 230 V
  • Input Voltage Range: FMI 180V-295V
  • Input Connection: 1W+N+G
  • Input Power Factor: ≥ 0.99 (with full linear load)
  • THDi: < 5% at full linear load and normal voltage
  • Input Frequency Range: 44 - 66 Hz
  • Input Resettable Breaker: Yes
DC Characteristics
  • DC Voltage: 72 V
  • Battery Connection: ANEN 4 Poles PP45
  • Standard Charging Current: 2 / 4 / 6 / 8 Adc (Selectable)
  • Additional Charging current (Optional): 8A -1No
Battery Type
  • 12 V VRLA
  • 12 V Tubular
Output Parameters
  • Output Connection: 1W+N
  • Output PF: 1
  • Output Frequency: 50/60 Hz ± 0,1%
  • Output Waveform Type: Sinusoidal
  • Overload capacity <105%: Continous
  • Overload capacity 106%-120%: 30 sec
  • Overload capacity >121%-150%: 10 sec
  • Overload capacity >150%: Immediate trip
  • Output Adjust: Yes
  • Output Voltage (in VAC): 220,230,240 V
Protections
  • Ingress Protection: IP 20
  • Input Low / High Protection: Yes
  • Output Low / High Protection: Yes
  • Overload Protection: Yes
  • Short Circuit Protection: Yes
  • Surge Protection: Yes
Communication Options
  • Modbus
  • SNMP
  • Dry Contacts
  • RS 232
  • USB
Environment Features
  • Operating Temperature: 0ºC to +40ºC
Physical Characteristics
  • Width (mm): 190
  • Depth (mm): 490
  • Height (mm): 590
  • Weight (kgs): 37.5
  • Colour: RAL 9017